Results
LiveRequired bending force
81.4 T
799 kN · 89.8 US tons
- Force per meter
- 81.4 T/m · 799 kN/m
- Die opening
- 80 mm (optimal)
- V / thickness ratio
- 8.0 × t
- Inside radius (air bend)
- ≈ 12.8 mm
- Minimum flange (90°)
- ≈ 62.2 mm
These are estimates. Confirm press brake and tooling limits for your material and setup.